LSG-3000 Moving Detector Goniophotometer lab for photometric ies light testing for dialux


Unit Price:

Not informed

FOB Price:

Not informed

Minimum Order Quantity:

1 Set/Sets

Type of Payment:

L/C (Letter of Credit)

D/A (Documents Against Acceptance)

D/P (Documents Against Payment)

T/T (Wire Transfer)

Preferred Port:

Not informed

Reference:

Not informed


Description

LSG-3000 Moving Detector Goniophotometer lab for photometric ies light testing for dialux Introduction:<br />
 <br />
LSG-3000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 requirement. The LSG-3000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.<br />
 <br />
  <br />
Measurement:<br />
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Lsocandela Diagrams, Efficient Luminescence Angle Etc.<br />
<br />
<br />
Features:<br />
•Many national patents pending on hardware and software.<br />
•CIE Class A & Constant temperature photo detector (Class L detector can be optional).<br />
•High degree of intelligent and test function is complete.<br />
•The rotation motor is from Japan MITSUBISHI MOTORS and it uses Germanic Angle decode system, it will help smoothly and high accuracy rotation. It is very stable when start and stop.<br />
•The working principles are according to IESNA and CIE. This instrument is specially recommended by LM-75, LM-79 and CIE121-1996.<br />
•With some optional instruments, it has good expanding functions<br />
•The position and working state remain the same as it is under working.<br />
•Special collimation device with laser cross line, conveniently and accurately fix the position of the tested luminaries.<br />
 <br />
 <br />
Specifications:<br />
•The tested luminaire rotates around the mirror with an angle of (γ)±180°(or 0-360°) and the tested luminaire rotates around itself with an angle of (C)±180°(or 0-360°).<br />
•The accuracy of angle: 0.1° Resolution of angle: 0.01°<br />
•Accuracy of photometry: CIE class A (Standard Class) or Class L.<br />
•The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux.<br />
•RS-232C standard interface can be connected to PC, English version software can run in WinXP or Win7<br />
<br />
LSG-3000 can be used with a USB CCD Spectrometer to test spatial CCT Distribution and other Spectral color parameters. We call this system "Goniospectroradiometer (LSG-19000CCD)". <br />
<br />
Please refer to this document: A Near-field Goniospectroradiometer for LED Measurements<br />
PDF version: A Near-field Goniospectroradiometer for LED Measurements <br />
 <br />
Online Vedio:  http://www.lisungroup.com/product-id-210.html<br />
 <br />
 <br />
LISUN LSG Series Goniophotometer:<br />
 <br />
Company Information<br />
Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & service offices in Hong Kong and Shanghai. The Lisun Group were award CE certificate. As a CIE Supportive Member, all of the test instruments of Lisun Group are designed according to CIE Standards. Lisun Group's products have been sold to more than 50 countries and regions in Europe, America, Australis, Africa,South America and Asia. Its quality is well accepted by many companies such as GE, Phillps, Sharp, OSRAM, SONY and so on.<br />
 <br />
Our Services<br />
 <br />
IES file test Service:<br />
we will test two lamps for you for free and supply you the following two kinds of test report.<br />
 <br />
1.    LM-79 IES or LDT files report for distribution curve intensity test by Goniophotometer System<br />
2.    LM-79 report for lumen, CCT, CRI, Spectrum test by Integrating Sphere & Spectroradiometer System LPCE-2(LMS-9000)

  • led testing instruments
  • goniophotometer
  • lighting intensity

Production Capacity:

30 sets/month

Delivery Timeframe:

Within 60 Days

Incoterms:

CFR - Cost and Freight

CIF - Cost, Insurance and Freight

CIP - Carriage and Insurance Paid to

DDU - Delivered Duty Unpaid

EXW - Ex Works

FOB - Free on Board

Packaging Details:

WOODEN


More about
Lisun Electronics Co., Ltd

icone de usuario

10-50

Employees

sales icon

200K - 500K

Sales volume (USD)

icone de exportar

80%

% Export sales

2003

Year

Established


Business type
  • Industry / Manufacturer
  • Other

Keywords
  • lighting testing instruments

Contact and location
  • icone de usuario Tracy Yu
  • icone de telefone +86 21 xxxxxxxx
  • map-marker shanghai / Shanghai | China

Make your Request!

Make your Request!

Start conversation
logo-Whatsapp icon-checked-none

Hello 👋!
Can we help you?

Fill in your name and phone number 😁

Start conversation Start conversation