Description
The JTY-HM-TX3703 linear beam smoke fire detector (hereinafter referred to as the detector) is a coded reflective linear infrared beam smoke detection
The detector must be used with the reflector.
The detector adopts a new and reasonable structure design, and is equipped with a unique laser module and digital tube indication during the debugging process, so that the debugging process is made
Simpler. This detector can be used in shopping malls, fitness centers, gymnasiums, exhibition halls, museums, hotel lobbies, printing houses, garment factories,
Warehouses and other places.
Second, the characteristics
1. Communication mode: non-polar two bus;
2. With automatic compensation function, it can automatically compensate for the influence caused by dust, vibration and other factors to a certain extent, which is improved
reliability of the detector;
3. Simple debugging, with concentric laser module indication, can easily find the optical path, there is a digital tube display, can indicate the reflected light intensity;
4. The sensitivity and distance value can be set through the handheld encoder on site;
5. PCB board full sealing protection process.
6. Support coding and non-coding application modes.
Third, technical parameters
1. Working voltage:
Bus: 15~28V Power supply: DC 20V~28V
2. Working current:
Bus current: ≤2mA
Supply Current: Monitor current≤23mA
Alarm current≤ 33mA
Debug current≤ 55mA
3. Optical path directional dependence angle: ±0.5 degrees (the data is taken as the average of the minimum declination angle on the left and right)
4. Response threshold: 2.3dB±0.5dB
5. Sensitivity level: 3 levels in total
Primary Sensitivity: The highest sensitivity
Secondary sensitivity: Medium sensitivity
Tertiary sensitivity: Lowest sensitivity
6. Coding method: electronic code (coding range is 1~254)
7. Fire alarm, fault contact output (output terminal is invalid when coding mode):
Fire alarm relay: contact capacity 30V/2A, normal terminal block HJ1, HJ2 normally open, closed under fire alarm state.
Fault relay: contact capacity 30V/2A, normal terminal GZ1, GZ2 normally open, closed under fault condition.
8. Use environment: temperature -10 °C ~ +55 °C, relative humidity ≤ 95% RH, non-condensing.
9. Color: gray
10. Enclosure protection level:
For general environmental applications, the enclosure protection rating is IP30;
For special environmental applications, the enclosure is IP66 after being glued.
11. Optical path length: 8m~100m
12. Weight: about 476g
13. Executive standard: GB 14003-2005
- Infrared linear smoke detector
- fire alarm
- smoke detector
- smoke alarm
- photoelectric smoke detector
- coded smoke detector
- tanda smoke alarm
- tanda smoke detector
Production Capacity:
Not informed
Delivery Timeframe:
Not informed
Incoterms:
EXW - Ex Works
FOB - Free on Board
Packaging Details:
Not informed
More about
Yiwu Yidun E-Commerce Firm
50-100
Employees
10M - 50M
Sales volume (USD)
70%
% Export sales
Year
Established
Business type
- Industry / Manufacturer
- Distributor / Wholesaler
Keywords
- fire alarm system
- smoke detector
- reflective beam smoke detector
- wireless video door phone
- wireless GSM home alarm system
- beam detector
- gas leak detector
- padlock seal
- security seals
- nap zapper Ver Mais
Contact and location
- wesley wong
- +86 xxxxxxxx
- shenzhen / guangdong | China